Author:HAWEN Block Mould Manufacturer TIME:2026-11-04
Dimensional accuracy matters because the corresponding interlocking sections must fit consistently during installation. Excessive variation can affect alignment, installation efficiency and the appearance of the completed wall or pavement. The important dimensions include the mating profiles as well as the overall length, width and height of the block.
A product drawing should show both sides of an interlocking connection, including the male and female sections or other matching surfaces. It should also identify the intended orientation of neighboring units. Two blocks with the same outside dimensions can still have different locating features, internal openings or edge profiles, so an overall-size sketch alone may not define the required mould.
Where more than one block is needed for the system, provide the associated drawings together. This makes it possible to discuss how the pieces meet instead of evaluating each shape in isolation. A finished sample can help communicate the intended arrangement, while the approved drawing records the geometry to be manufactured.
Send the complete block sections, drawings of the mating surfaces and any specified acceptance requirements. Include the machine model, pallet dimensions and existing mould information for the production-interface review. The required dimensional limits should be agreed for the particular product and process; a general interlocking-block description is not a universal tolerance specification.
See Interlocking Block Mold for the relevant mould range and drawing requirements.